Error Messages Of The Scalance X300 / X400 - Siemens SCALANCE X-300 Configuration Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-300:
Table of Contents

Advertisement

Appendix D
D.1

Error messages of the SCALANCE X300 / X400

Note
If link aggregation is activated, instead of a port number, you can also specify the number of
the aggregation (for example AG1).
Messages when an error occurs and following elimination of an error
Table D- 1
Message when an error occurs
Link down on <port number>.
Non-recoverable ring error on <port number>.
Other redundancy manager detected ...
MAC <MAC address> on <port number>.
<HRP> ring manager activated.
<HRP> ring manager enters active state.
Standby device enters active state.
Standby is waiting for <master | slave>.
Standby <partner | observer> lost connection
to <master | slave> <MAC address> on <port
number>.
Unsupported version <version number> for
standby protocol detected.
Second observer detected.
MAC <MAC address> at <port number>.
Observer: RM switches frames on isolated port.
Unexpected traffic received on observer <port
number>.
Observer: Timeout for test frames detected on
port <port number> while RM signals "passive".
Observer: RM signals active but RM test frames
are received on both ring ports.
Observer: RM runs incompatible software version
<version number>.
Observer: RM test frame timeout on both ring
ports.
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
Error messages assigned to an error status (error LED)
Messages after eliminating the problem
Link up on <port number>.
Ring error on <port number> gone.
Other redundancy manager gone ...
MAC <MAC address> on <port number>.
<HRP> ring manager falls back to client.
<HRP> ring manager falls back to passive state.
Standby device enters passive state.
Standby connection established to <master |
slave> <MAC address> on <port number>.
Standby <partner | observer> reconnected to
<master | slave> <MAC address> on <port num-
ber>.
Unsupported version <version number> for
standby protocol gone.
Second observer gone.
MAC <MAC address> at <port number>.
Observer: RM stopped switching on isolated port.
Unexpected traffic on observer <port number>
gone.
Observer: Timeout for test frames on port <port
number> is gone.
Observer: RM signals right state.
Observer: RM's incompatible software version
<version number> gone.
Observer: RM test frames received.