Configuration using Web Based Management and Command Line Interface
4.3 The X-300/X-400 menu
No. of Signaled Faults
Indicates how often the signaling contact of the IE switch responded.
The counter is reset each time the device is restarted.
No. of Changes to RM Active State
A value is displayed here only when the IE switch operates as HRP manager (see section
"X-300/X-400 ring configuration").
The value indicates how often the HRP manager changed to the active state. This state is
adopted when the redundancy manager detects an interruption on the line connected to the
ring ports.
The counter is reset each time the device is restarted.
Max. Delay of RM Test Packets[ms]
Here, a value is displayed only when the IE switch operates as HRP manager ("Redundancy
Manager enabled" check box selected).
In redundancy manager mode, an IE switch sends test frames via the ring ports to the
connected line of switches and measures the delay of these test frames. The maximum
delay that occurs with these test packets is displayed.
No. of Changes to Standby Active State
A value is displayed here when the standby function is enabled (see section "X-300/X-400
Standby Mask").
The value specifies how often the IE switch has changed the standby status from passive to
active. This status is adopted when the connection of a standby port of the standby master
fails.
The counter is reset each time the device is restarted.
No. of STP/RSTP/MSTP Topology Changes
Shows how often reconfiguration occurred due to the spanning tree mechanism.
Reset Counters
Click this button to reset the counters of the IE switch. A restart, for example due to an
interruption of the power supply to the IE switch, causes the counters to be reset.
Syntax of the Command Line Interface
Table 4- 19
Command
counters
resetc
84
X-400 Counters - CLI\X-400> or X-300 Counters - CLI\X-300>
Displays the following counter readings:
Changes to RM active state

 I ndicates how often the IE switch operating as redundancy
manager closed the ring.
Max. delay of RM Test Packets

 I ndicates the maximum delay of test frames sent by the redun-
dancy manager.
Resets the IE switch counters.
Description