Configuration using Web Based Management and Command Line Interface
4.4 The Agent menu
You will find further information on PTP in the sections "Precision Time Protocol (PTP)
complying with IEEE 1588 (Page 236)" and "Configuration of the Precision Time Protocol
with the WBM (Page 242)".
Note
Avoiding time jumps
To avoid time jumps, make sure that there is only one time server (SICLOCK time
transmitter, (S)NTP server, PTP master) in the network.
If there are several time servers in the network, only activate one time protocol.
DHCP
If you enable this check box, the IE switch browses the network for a DHCP server and
configures its IP parameters according to the data supplied by this server. For detailed
information on this functionality, refer to the section "Assigning addresses with the DHCP
client of the IE switch".
Note
As soon as the IP address has been assigned once by a PROFINET IO controller, DHCP
automatically deactivates itself and must be reactivated if required.
BOOTP
If you enable this check box, the IE switch browses the network for a BOOTP server and
configures its IP parameters according to the data supplied by this server. For detailed
information on this functionality, refer to the section "Assigning addresses with the BOOTP
client of the IE switch".
DCP
If you select this option, the device can be accessed and configured via DCP (PST Tool and
STEP 7).
DCP Read Only
If you select this option, the configuration data can only be read via DCP (PST Tool and
STEP 7).
Default Gateway
If you require the IE switch to communicate with devices (diagnostics stations, e-mail
servers, etc.) in a different subnet, you will need to enter the IP address of the default
gateway here.
Agent VLAN ID
Enter the VLAN-ID of the agent here.