Siemens SCALANCE X-300 Configuration Manual page 201

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-300:
Table of Contents

Advertisement

Edge
The following entries are possible in this column:
● yes

 A n edge port is connected to this port.
● no
There is a spanning tree or rapid spanning tree device on this port.
If an edge port is connected, an IE switch can switch over the port more quickly without
taking into account spanning tree frames. If a spanning tree frame is received despite this
setting, the port automatically changes to the no setting for switches.
P.t.P.
There is a point-to-point link when two RSTP-compliant network components are connected
together over this port. There are 2 possible statuses :
● Yes

 T here is a point-to-point link.
● No

 T here is not a point-to-point link.
Syntax of the Command Line Interface
Table 4- 62
info
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
Configuration using Web Based Management and Command Line Interface
(Rapid) Spanning Tree Port Parameters - SWITCH\STP\PORTS>
Command
Shows an overview of the ports and the corresponding
rapid spanning tree settings.
Description
4.5 The Switch menu
Comment
-