Syntax of the Command Line Interface
Table 4- 88
Command
info [ports]
pseusage [percent]
status [<E|D> [ports]]
prio [<LOW|HIGH|CRITICAL>
[ports]]
type <port> [string]
manmode [<E|D>]
apower [<power> [ports]]
copower [<power> [ports]]
assign [<port>]
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
Configuration using Web Based Management and Command Line Interface
CLI\POE>
Description
Displays information about PoE for the rele-
vant port.
Sets a value (percentage) for the Usage
Threshold parameter. As soon as the power
being used by the connected devices ex-
ceeds this percentage of the maximum pow-
er, an event is triggered.
If you call this command without parameters,
the current value is displayed.
Enables/disables PoE power supply for the
specified port.
Sets the priority for the power supply for the
specified port. If no port is specified, the
value applies to all ports.
Specifies a string describing the connected
device in greater detail. The maximum length
is 64 characters.
Enables/disables the "Manual Power Alloca-
tion Mode" for a port.
If the "Manual Power Allocation Mode" is
enabled, you can set the power values for the
PoE ports manually.
Assigns a port a specific power in mW ("Allo-
cated Power").
Range of values: 1000 mW - 20000 mW
Specifies the cut-off power for a port in mW.
If the cut-of power is exceeded, the port is
disabled.
Range of values: 1000 mW - 20000 mW
The power that a port currently uses is per-
manently assigned to the port as "Allocated
Power".
4.6 The PoE menu item
Comment
-
Administrator only.
Administrator only.
Administrator only.
Administrator only.
Administrator only.
Administrator only.
Administrator only.
Administrator only.