Command
edit <areaID> [type] [E|D]
[metric]
delete <areaID>
Example
The command
add 0.0.0.3 Stub d 2
generates a stub area "0.0.0.3" for which no summary LSAs are generated. The default
route is assigned metric "2".
4.7.8

OSPFv2 Area Ranges

Overview
You can create address ranges in the "Area Ranges" dialog that allow various address
ranges to be grouped when propagating. This allows the number of summary LSAs in the
areas to be reduced.
Figure 4-138 OSPFv2 Area Ranges
Area ID
Area ID to which the address range relates.
Subnet Address
Address of the network area to be grouped.
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
Configuration using Web Based Management and Command Line Interface
Description
Modifies an area.
Possible types:
Standard
Stub
NSSA
The [E|D] and metric parameters are possible
only for a stub area.
E
Enable importing summary
D
Disable importing summary
Deletes an area
4.7 The Router menu (SCALANCE X414-3E)
Comment
Administrator only.
Administrator only.