The screen contains the following boxes:
● IP address
Enter the IP address of the IP address of the server in the "IP address" input box.
● Destination port
Enter the input port on the RADIUS server in the "Destination port" input box.
As default, input port 1812 is set. The range of values is 1 to 65535.
● Shared Secret
Enter your access identifier in the "Shared Secret" input box.
● Confirm Shared Secret
Enter the access identifier again as confirmation in the "Confirm Shared Secret" input
box.
● Maximum retransmissions
In the "Maximum retransmissions" input box, enter the maximum number of
retransmissions before another configured RADIUS server is queried or the logon counts
as having failed.
2 is set as default. The range of values is 1 to 254.
RADIUS Server
You can enter data for two RADIUS servers. The information in the "Backup" column is used
if the server defined in the "Primary" column is not available.
RADIUS server for "Login Mode"
The RADIUS server specified here serves at the same time as the authentication server for
the login modes "RADIUS and Local" and "RADIUS", see section System Passwords &
Login Mode (Page 52).
Syntax of the Command Line Interface
Table 4- 41
Command
info
server [<ip>[:port]]
serverb [<ip>[:port]]
secret <string>
secretb <string>
maxret [number]
maxretb [number]
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
Configuration using Web Based Management and Command Line Interface
802.1x RADIUS Configuration - CLI\SWITCH\DOT1X\RADIUS>
Description
Displays the current RADIUS settings.
Specifies the IP address and port of the primary server.
Specifies the IP address and port of the backup server.
Specifies the password for the primary server.
Specifies the password for the backup server.
Maximum number of requests to the primary server.
Maximum number of requests to the backup server.