Comtech EF Data CDM-625A Installation And Operation Manual page 359

Advanced satellite modem (18 kbps – 25 mbps)
Hide thumbs Also See for CDM-625A:
Table of Contents

Advertisement

CDM-625A Advanced Satellite Modem
Serial-based Remote Product Management
Command
Number of
Parameter
(Instruction
Arguments
& Qualifier)
...Global
Configuration
(cont.)
OGC Outdoor Unit
OGC=
50 Bytes
Global Copy
Description of Arguments
BBBCCC=CnC search delays
D=CnC PMSI mode
ee=Compressed Ethernet port speed
E=Attach summary BUC alarm to Tx
F=Attach summary LNB alarm to Rx
GG=WAN buffer length
H=Dedicated Management Port
NOTE: Much of the CDM-625A MGC format carries over from the 600/L MGC format, except where "*" indicates the
differences. For "**ee=Compressed Ethernet port speed" Ethernet port speed is compressed from 4 bytes in SEC
command to 2 bytes in MGC. The first byte represents speed settings for Ports 1 and ; the second byte represents speed
settings for Ports 3 and 4. In each byte, character A through Y is used to represent 25 possible combinations of two port
speed. A=00, B=01, C=02, D=03, E=04, F=10, G=11, H=12, I=13, J=14, K=20, L=21, M=22, N=23, O=24, P=30, Q=31,
R=32, S=33, T=34, U=40, V=41, W=42, X=43, Y=44.
EXAMPLE: BN is converted to 0123, that means Port 1 is AutoNeg, Port 2 is 100Full, Port 3 is 100Half, Port 4 is 10Full.
Command or Query.
ODU Global Configuration of CDM-625A, in the form shown in the Response to Query column (to the right), where:
aa=BUC Address
b=BUC Tx Output Enable
x (spare)*
d=BUC Power Supply
e=BUC 10MHz Reference State
xxxxx (spares)
gggg=BUC Current - Low Limit
hhhh=BUC Current - High Limit
xxxx (spares)*
i=LNB Power Supply*
x (spare)*
k=LNB 10MHz Reference
lll=LNB Low Alarm Limit
nnn=LNB High Alarm Limit
FFFFFS=TX LO Frequency
fffffs=RX LO Frequency
xxxxxx (spares)
NOTES:
1) Much of the CDM-625A OGC format carries over from the CDM-600L OGC format, except where "*" indicates the
differences. In 600L Emulation Mode, the OGC format follows the CDM-600L OGC format.
2) Any unavailable parameters will be filled with x's.
same as CSD
same as CPM
see ** Note
same as ABA
same as ALA
same as WBL
same as DMP
same as BAD
same as BOE
same as BPS
same as BFR
same as BCL
same as BCH
same as LPS
same as LNR
same as LNL
same as LNH
same as TLO
same as RLO
8–45
MN-CDM625A
Revision 4
Query
Response to
(Instruction &
Response to Query
Command
Qualifier)
OGC=
OGC?
OGC=aabxdexxxxxggg
OGC?
OGC?n (where n=0
ghhhhxxxxixklllnnnFFF
OGC*
thru 9. Returns the
FFSfffffsxxxxxx
OGC#
OGC portion of 1 of
10 stored
(Returns current OGC
configurations)
Configuration)