Comtech EF Data CDM-625A Installation And Operation Manual page 336

Advanced satellite modem (18 kbps – 25 mbps)
Hide thumbs Also See for CDM-625A:
Table of Contents

Advertisement

CDM-625A Advanced Satellite Modem
Serial-based Remote Product Management
Command
Length of
Parameter
(Instruction
Argument
& Qualifier)
...Rx FEC
Code Rate
(cont)
Rx Data Rate
RDR=
9 bytes
Rx Symbol
RSR=
9 bytes, numeric
Rate
Rx Frequency
RFQ=
9 bytes
Exception –
600 Emulation:
8 bytes
Rx Data Invert
RDI=
1 byte, 0 or 1
Exception –
600/L Emulation:
IRD=
Rx Sub-Mux
RMX=
1 byte, 0 or 1
on/off
Description of Arguments
z=VersaFEC-2 ModCod 30 – 32-ARY 0.708
"=VersaFEC-2 ModCod 31 – 32-ARY 0.733
&=VersaFEC-2 ModCod 32 – 32-ARY 0.757
@=VersaFEC-2 ModCod 33 – 32-ARY 0.782
[=VersaFEC-2 ModCod 34 – 32-ARY 0.801
]=VersaFEC-2 ModCod 35 – 32-ARY 0.831
{=VersaFEC-2 ModCod 36 – 32-ARY 0.855 (Long Block only)
}=VersaFEC-2 ModCod 37 – 32-ARY 0.879 (Long Block only)
Depending on FEC type, not all of these selections will be valid.
EXAMPLE: <0/RCR=1 (selects Rate 3/4)
Command or Query (Query only in ACM).
Sets or returns Rx Data Rate, the formxxxxx.xxx, where:
xxxxx.xxx=Value, in kbps, from 18 kbps to 25 Mbps
Resolution=1 bps
EXAMPLE: <0/RDR=02047.999.
NOTES:
1) Additional auxiliary G.703 sub-rates are available, selected using:
00512.AUX 01024.AUX 02048.AUX
2) If set for QDI (Quad D&I), RDR is query only.
3) The connectors used for the Aux rates are IDI/DDO.
4) These Aux rates are not available with D&I or IDR.
Query only (Command or Query in IP-ACM or VersaFEC-2 ACM).
Allows remote access to the Rx Symbol Rate in the form ddddd.ddd
NOTE: Symbol Rate ranges in IP-ACM=37 ksym/sec to 4100 ksym/sec
Symbol Rate ranges in VersaFEC-2 ACM Short Block=37 ksym/sec to 1000 ksym/sec
Symbol Rate ranges in VersaFEC-2 ACM Long Block=37 ksym/sec to 125000 ksym/sec
Command or Query.
Sets or returns Frequency ranges in the form xxxx.xxxx where:
70/140 MHz Unit range is from 50 MHz to 180 MHz, and
L-Band (FAST option) Unit range is from 950 MHz to 2250 MHz
Resolution=100Hz.
EXAMPLE: <0/RFQ=0950.9872
Command or Query.
Invert Receive Data in the form x, where:
0=Normal
1=Inverted
EXAMPLE: <0/RDI=1 (selects Inverted RX Data)
Command or Query.
Sets or returns Rx Sub-Mux in the form x, where:
0=Off
1=On
8–22
MN-CDM625A
Revision 4
Query
Response to
(Instruction &
Response to Query
Command
Qualifier)
RDR=
RDR?
RDR=xxxxx.xxx
RDR?
RDR*
(see Description of
RDR#
Arguments)
RSR=
RSR?
RSR=ddddd.ddd
RSR?
(see Description of
RSR*
Arguments)
RSR#
RFQ=
RFQ?
RFQ=xxxx.xxxx
RFQ?
(see Description of
RFQ*
Arguments)
RFQ#
Exception –
600 Emulation:
RFQ=xxx.xxxx
RDI=
RDI?
RDI=x
RDI?
RDI*
Exception –
(see Description of
RDI#
600/L Emulation:
Arguments)
IRD?
RMX?
RMX?
RMX=x
RMX=
RMX*
(see Description of
RMX#
Arguments)