CDM-625A Advanced Satellite Modem
Front Panel Operation
CONFIG: Tx  Power  Mode  AUPC  Alarm-Action (IP-ACM or
V2-ACM Mode)
Tx-Alarm: Max Power (MaxPwr,MinMCod,None)
Rem Demod Unlock Act=NomPwr(Nom,Max,Hold)
On the top line – Use the ▲▼ arrow keys to select the alarm action that occurs if the AUPC
causes the maximum output power level to be reached. Valid settings are:
Setting
MaxPwr
MinMCod
None
On the bottom line
demodulator is unlocked. Use the ▲▼ arrow keys to select a parameter. Valid settings are:
Setting
Nom
Max
Hold
CONFIG: Tx  Power  Mode  CnC-APC Mode
Appendix F. Double Talk Carrier-in-Carrier Option
When you select CnC Automatic Power Control (CnC-APC) mode, this menu appears as shown:
Output Power Mode = CnC-Auto-Power-Control
Level=-25.0dBm MaxPwrIncrease=2.5dB ()
On the bottom line – Edit the power output level and the maximum permitted increase in
power level when in APC Mode. Use the
arrow keys to change that digit. Press ENTER.
Note that, when APC is in an active state, the power level values display in the bottom left as
'AUTO'.
Alarm Function
(Maximum Power) Generates alarm when maximum power is reached.
(Minimum ModCod) Generates alarm if minimum ModCod is reached.
Generates no alarm.
Use the ▲▼ arrow keys to select the action that occurs if the remote
Function
(Nominal Power) The output level reverts to the nominal power level set under Manual.
(Maximum Power)The output level changes to the permitted maximum.
The output level is maintained at the value just before the remote demod lost lock.
◄ ►