Comtech EF Data CDM-625A Installation And Operation Manual page 349

Advanced satellite modem (18 kbps – 25 mbps)
Hide thumbs Also See for CDM-625A:
Table of Contents

Advertisement

CDM-625A Advanced Satellite Modem
Serial-based Remote Product Management
Command
Length of
Parameter
(Instruction
Arguments
& Qualifier)
POCO
PCO=
1 byte, 0 or 1
feature
(Power-On
Carrier-Off)
DoubleTalk
CNM=
1 byte, 0 thru 9
Carrier-in-
Carrier (CnC)
Mode
DoubleTalk
CPM=
1 byte, 0 thru 3
Carrier-in-
Carrier (CnC)
PMSI Mode
CnC
CCF=
3 bytes
Frequency
Range/offset
CnC
CSD=
6 bytes
Min/Max
Search Delay
Description of Arguments
Command or Query.
When enabled, when a modem is power cycled, it powers up with the Tx carrier setting OFF.
0=POCO disabled (normal operation)
1=POCO enabled – Use with caution!
EXAMPLE: <0/PCO=0 (disabled – normal operation)
Command or Query.
Sets or returns CnC operation in the form x, where:
0=Off
1=On (normal)
2=APC, C-Band, Side A
3=APC, X-Band, Side A
4=APC, Ku-Band, Side A
5=APC, Ka-Band, Side A
6=APC, C-Band, Side B
7=APC, X-Band, Side B
8=APC, Ku-Band, Side B
9=APC, Ka-Band, Side B
NOTES:
1) CnC may be enabled only if:
• The optional plug-in hardware CnC card has been installed AND a CnC FAST option is unlocked.
• The range of permitted data rates is controlled by a FAST feature code. (Read EID to decode the installed
options for the modem)
2) If CnC-APC is active (APS=22), key transmission/reception (Modulation, FEC type, Code Rate, Framing, Data Rate,
Interface) cannot be modified until CnC-APC is suspended. (Use APC command to suspend or activate.)
Command or Query. (CnC parameter)
Sets or returns CnC PMSI (Pre-Mapped-Symbol Interface) mode in the form x, where:
0=Idle
1=Redundancy (1:1 or 1:N)
2=Talk
3=Listen
Command or Query. (CnC parameter)
Sets or returns the maximum value that may be entered, in the form xxx, as the CnC Sweep frequency range depends on
the Rx symbol rate as follows:
±1 to the symbol rate (ksps)/2
18ksps to 64ksps:
64ksps to 389ksps:
±1 to 32 kHz
389ksps to 2000ksps:
±1 to 10% of sym rate
>2000ksp
±1 to 200 kHz
EXAMPLE: <0/CCF=030
Command or Query.
(CnC parameter)
Sets or returns CnC min/max delay value in milliseconds, in the form xxxyyy, where:
xxx=minimum delay
yyy=maximum delay
Maximum allowable value is 330ms
EXAMPLE: <0/CSD=010325
8–35
MN-CDM625A
Revision 4
Query
Response to
(Instruction &
Response to Query
Command
Qualifier)
PCO=
PCO?
PCO=x
PCO?
(see Description of
PCO*
Arguments)
PCO#
CNM=
CNM?
CNM=x
CNM?
(see Description of
CNM*
Arguments)
CNM#
CPM=
CPM?
CPM=x
CPM?
(see Description of
CPM*
Arguments)
CPM#
CCF=
CCF?
CCF=xxx
CCF?
(see Description of
CCF*
Arguments)
CCF#
CSD=
CSD?
CSD=xxxyyy
CSD?
(see Description of
CSD*
Arguments)
CSD#

Advertisement

Table of Contents
loading