Preventive Maintenance Schedule; Pm Table - Ricoh B003 Service Manual

Hide thumbs Also See for B003:
Table of Contents

Advertisement

2. PREVENTIVE MAINTENANCE SCHEDULE

2.1 PM TABLE

NOTE: Amounts mentioned as the PM interval indicate the number of prints.
Symbol key: C: Clean, R: Replace, L: Lubricate, I: Inspect
B003/B004B006/B007
SCANNER/OPTICS
Reflector
1st Mirror
2nd Mirror
3rd Mirror
Scanner Guide Rails
Platen Sheet Cover
Exposure Glass
Toner Shield Glass
APS Sensor
Exposure Glass (Sheet
through)
DRUM (OPC) AREA
Charge Roller
Charge Roller Cleaning
Pad
Quenching Lamp
Pick-off Pawls
Spurs
ID Sensor
CLEANING UNIT
Drum Cleaning Blade
Cleaning Entrance Seal
Side Seal
SM
CÓPIA NÃO CONTROLADA
EM
150K
300K
450K
C
C
C
C
C
C
C
C
I
I
C
I
I
C
C
C
C
C
C
C
C
R
R
R
R
C
R
R
C
C
C
C
R
R
C
C
I
I
2-1
CÓPIA NÃO CONTROLADA
NOTE
C
Optics cloth
C
Optics cloth
C
Optics cloth
C
Optics cloth
Do not use alcohol. Lubricate
I
if necessary.
Dry cloth or alcohol. Replace
I
platen sheet if required.
C
Dry cloth or alcohol
C
Optics cloth
C
Dry cloth or alcohol
Dry cloth or alcohol
C
R
R
Dry cloth
R
C
Dry cloth or alcohol
Perform SP3-001-2 after
C
blower brush cleaning.
R
Blower brush. Replace if
C
required.
I
B003/B004/B006/B007
PM TABLE

Advertisement

Table of Contents
loading

This manual is also suitable for:

B004B006B007

Table of Contents