Commissioning
6.2 Commissioning on PROFIBUS DP
Figure 6-5
Setting the PROFIBUS DP address
You change the PROFIBUS DP address in exactly the same way as you set it. A change in
the PROFIBUS DP address becomes valid for the ET 200S after a POWER ON at the
interface module / COMPACT module.
6.2.2.2

Commissioning ET 200S on PROFIBUS DP

Software Requirements
The table below details the software requirements for commissioning on PROFIBUS DP.
Table 6-2
Software requirements for commissioning on PROFIBUS DP
Configuration software
used
STEP 7
Configuration software for
a different DP master used
6-10
Setting the PROFIBUS address
Version
from Version 5.0 and
ServicePack 3
You use HW Config. With Service Pack 3 or higher the ET 200S is
included in the hardware catalog.
You need the GSD file of ET 200S.
Operating Instructions, 12/2005, A5E00515771-03