D-Link DGS-1510/ME Series Reference Manual page 89

Table of Contents

Advertisement

DGS-1510/ME Series Metro Ethernet Switch CLI Reference Guide
conform - (Optional) Specifies the action when a packet is mapped to the "green" color.
permit - Permits the packet.
replace_dscp - Specifies to change the DSCP of the packet.
<value 0-63> - Enter the replace DSCP value here. This value must be between 0 and 63.
counter - (Optional) Specifies the ACL counter. This is optional. The default is "disable". The resource may
be limited so that a counter cannot be turned on. Counters will be cleared when the function is disabled.
enable - Specifies that the ACL counter option will be enabled.
disable - Specifies that the ACL counter option will be disabled.
exceed - Specifies the action when a packet is mapped to the "yellow" color.
permit - Specifies to permit the packet.
replace_dscp - (Optional) Specifies to change the DSCP of the packet.
<value 0-63> - Enter the replace DSCP value here. This value must be between 0 and 63.
drop - Specifies to drop the packet.
counter - (Optional) Specifies the ACL counter. This is optional. The default is "disable". The resource may
be limited so that a counter cannot be turned on. Counters will be cleared when the function is disabled.
enable - Specifies that the ACL counter option will be enabled.
disable - Specifies that the ACL counter option will be disabled.
violate - Specifies the action when a packet is mapped to the "red" color.
permit - Specifies to permit the packet.
replace_dscp - (Optional) Specifies to change the DSCP of the packet.
<value 0-63> - Enter the replace DSCP value here. This value must be between 0 and 63.
drop - Specifies to drop the packet.
counter - (Optional) Specifies the ACL counter. This is optional. The default is "disable". The resource may
be limited so that a counter cannot be turned on. Counters will be cleared when the function is disabled.
enable - Specifies that the ACL counter option will be enabled.
disable - Specifies that the ACL counter option will be disabled.
delete - Specifies to delete the specified flow_meter.
Restrictions
Only Administrators, Operators and Power-Users can issue this command.
Example
To configure a "two rate, three color" flow meter:
DGS-1510-28XMP/ME:admin# config flow_meter profile_id 1 access_id 1 tr_tcm cir 1000 cbs 2000
pir 2000 pbs 2000 color_blind conform permit counter enable exceed permit replace_dscp 60
counter enable violate drop
Command: config flow_meter profile_id 1 access_id 1 tr_tcm cir 1000 cbs 2000 pir 2000 pbs
2000 color_blind conform permit counter enable exceed permit replace_dscp 60 counter enable
violate drop
Success.
DGS-1510-28XMP/ME:admin#
6-6
show flow_meter
Description
This command is used to display the flow-based metering (ACL Flow Metering) configuration.