D-Link DGS-1510/ME Series Reference Manual page 321

Table of Contents

Advertisement

DGS-1510/ME Series Metro Ethernet Switch CLI Reference Guide
advertisements on any given port. The default value is 30 seconds.
<sec 5-32768> - Enter the message transmit interval value here. This value must be between 5 and 32768
seconds.
message_tx_hold_multiplier - Specifies to configure the message hold multiplier. The default value is 4.
<int 2-10> - Enter the message transmit hold multiplier value here. This value must be between 2 and 10.
tx_delay - Specifies the minimum interval between sending of LLDP messages due to constantly change of MIB
content. The default value is 2 seconds.
<sec 1-8192> - Enter the transmit delay value here. This value must be between 1 and 8192 seconds.
reinit_delay - Specifies the minimum time of reinitialization delay interval. The default value is 2 seconds.
<sec 1-10> - Enter the re-initiate delay value here. This value must be between 1 and 10 seconds.
Restrictions
Only Administrators, Operators and Power-Users can issue this command.
Example
To change the packet transmission interval:
DGS-1510-28XMP/ME:admin# config lldp message_tx_interval 30
Command: config lldp message_tx_interval 30
Success.
DGS-1510-28XMP/ME:admin#
38-4
config lldp notification_interval
Description
This command is used to configure the timer of notification interval for sending notification to configured SNMP trap
receiver(s).
Format
config lldp notification_interval <sec 5-3600>
Parameters
<sec 5-3600> - Enter the notification interval value here. This value must be between 5 and 3600 seconds. The
default setting is 5 seconds.
Restrictions
Only Administrators, Operators and Power-Users can issue this command.
Example
To changes the notification interval to 10 second:
317

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents