Scalar i2000 User's Guide
If the library is not offline, you receive a message
Note
that asks you whether you want to take it offline.
Click Yes.
5 At the prompt, make sure that all data input and output has stopped.
Click Yes to continue.
When the system determines that it can reconfigure the library using the
saved image, a message dialog box appears that informs you that the
library will reboot itself. The reset could take minutes to complete. If you
are near the library and can see the library's touch screen, normal behavior
is when two "working" messages appear and the touch screen goes dark
when the LMC server restarts. From the remote client, a message appears
that indicates that the LMC server is reconnecting to the client. After it
reconnects, the LMC server performs a discovery.
As the MCB reboots, the I/O blades, MCB, LMC server, and robotics
control unit (RCU) change to the configuration settings stored in the
rescue image. Each I/O blade is also reset.
When the LMC has restarted, reconnected, and completed its discovery
operation, a message appears that indicates that the library has been
restored to its previous configuration.
If the operation succeeds, a message appears that indicates that the
operation completed successfully.
If the operation fails at any point, the library generates a RAS ticket that
contains details about the failure. Perform a revert or rescue operation to
return the library to a stable configuration.
6 If you have not done so already, make sure that the robotics are
enabled and bring the library back online so that data input and
output can recommence.
Chapter 5 Maintaining Your Library
Maintenance Actions
263