Terminal
Signal
1W
Potentiometer
signal
1X
Hazard warning
SW signal
2A
Panel light control
signal
2B
TNS signal
2C
Motor drive signal Air mix actuator
2D
Motor drive signal Air mix actuator
2E
Motor drive signal Airflow mode
2F
Backup power
supply
2G
Motor drive signal Airflow mode
U–50
CONTROL SYSTEM
Connected to
Airflow mode
VENT mode
actuator
BI-LEVEL mode
HEAT mode
HEAT/DEF mode
DEFROSTER mode
Hazard warning
Hazard warning switch is
switch
off
Hazard warning switch is
on
Panel light control
Headlight switch ON and
switch
panel light control switch
at max. illumination
Headlight switch ON and
panel light control switch
at min. illumination
TNS relay
Headlight switch OFF
Headlight switch ON
Moving to COLD
Moving to HOT
Moving to HOT
Moving to COLD
Moving to DEFROSTER
actuator
Moving to VENT
ROOM 15 A fuse
Under any condition
Moving to VENT
actuator
Moving to DEFROSTER
Test condition
Voltage (V)
Below 1.0
10.2
Below 1.0
Below 1.0
Below 1.0
Below 1.0
Below 1.0
Action
• Inspect for continuity or
4.3
short circuit (Climate control
3.3
unit—airflow mode actuator:
2.3
1W—C)
• Inspect airflow mode
1.5
actuator
• Inspect terminal voltage of
0.6
climate control unit (1B)
• Inspect for continuity or
short circuit (Climate control
12
unit—flasher unit: 1X—H)
• Inspect flasher unit
• Inspect terminal voltage of
climate control unit (1T)
• Inspect center panel
• Inspect for continuity
(Climate control unit— panel
light control switch: 2A—C)
0.2
(Panel light control switch—
ground: C—GND)
• Inspect panel light control
switch
• Inspect for short circuit
(Climate control unit— panel
light control switch: 2A—C)
• Inspect for short circuit
(Climate control unit—TNS
relay: 2B—D)
• Inspect TNS relay
• Inspect headlight switch
• Inspect for continuity or
short circuit (Climate control
12
unit—TNS relay: 2B—D)
• Inspect TNS relay
• Inspect headlight switch
• Inspect for continuity or
12
short circuit (Climate control
unit—air mix actuator: 2D—
D, 2C—F)
• Inspect air mix actuator
• Inspect for continuity or
12
short circuit (Climate control
unit—air mix actuator: 2C—
F, 2D—D)
• Inspect air mix actuator
• Inspect for continuity or
12
short circuit (Climate control
unit—airflow mode actuator:
2E—F, 2G—D)
• Inspect airflow mode
actuator
• Inspect for continuity or
short circuit (Climate control
B+
unit—fuse: 2F— ROOM 15
A fuse)
• Inspect ROOM 15 A fuse
• Inspect for continuity or
12
short circuit (Climate control
unit—airflow mode actuator:
2G—D, 2E—F)
• Inspect airflow mode
actuator

Advertisement

Table of Contents
loading

Table of Contents