DLT Cartridge Environmental Specifications
The following specifications refer to the operating and storage environments for
DLT cartridges.
Table A-3. DLT Cartridge Environmental Specifications
Operating environment
Temperature
Relative humidity
Wet-bulb temperature
Storage environment
Temperature
Relative humidity
Wet-bulb temperature
Storage environment for
cartridges intended for
archiving data one year or more
Temperature
Relative humidity
CAUTION:
Potential damage to cartridges: When storing DLT cartridges, the stray
magnetic field at any point on the tape shall not exceed 4000A/m.
Super DLT Cartridge Environmental Specifications
Operating environment
Temperature
Relative humidity
Wet-bulb temperature
Storage environment (archive)
Temperature
Relative humidity
Wet-bulb temperature
Storage environment (non-archive)
Temperature
Relative humidity
Wet-bulb temperature
For more information about DLT cartridges, visit:
http://www.quantum.com
95895
10º to 40ºC (50º to 104ºF)
20% to 80% noncondensing
25º C (77ºF) maximum
16º to 32ºC (61º to 90ºF)
20% to 80% noncondensing
26º C (79º F) maximum
18º to 26ºC (64º to 79ºF)
40% to 60%
10º to 40ºC (50º to 104ºF)
20% to 80%
26ºC (79ºF) maximum
18º to 28ºC (64º to 82ºF)
40% to 60%
26ºC (78.8ºF) maximum
16º to 32ºC (60º to 90ºF)
20% to 80%
26ºC (79ºF) maximum
Ninth Edition
DLTtape Cartridges
A-9