20.3.4
Converter Firmware (MJ-1101)
The harness jig for board connection is required for updating the firmware of the converter PC board of
the finisher (MJ-1101) as well as the download jig (K-PWA-DLM-320).
Harness jig for board connection
Important:
•
Be sure to connect the equipment and finisher (MJ-1101) before updating the converter
firmware.
•
Be sure to shut down the equipment before installing and removing the download jig.
•
Do not shut down the equipment during the update. The data could be damaged and not be
operated properly.
[A] Update Procedure
(1)
Install the ROM to the download jig (K-PWA-DLM-320).
Make sure the direction is correct.
(2)
Press the [ON/OFF] button on the control panel to shut down the equipment.
(3)
Take off the finisher board access cover.
(4)
Take off the rear cover-1 of the equipment.
e-STUDIO2330C/2820C/2830C/3520C/3530C/4520C
FIRMWARE UPDATING
Name of the jig
Board access cover
Fig. 20-22
Fig. 20-23
20 - 38
Model name
HRNS-CNV-DL-JIG
Rear cover-1