Toshiba e-STUDIO2330C Service Manual page 696

Hide thumbs Also See for e-STUDIO2330C:
Table of Contents

Advertisement

Classific
Code
ation
7295
Image
Range
correction
adjustment
(Automatic
density
adjustment)
7296
Image
Range
correction
adjustment
(Manual
density
adjustment)
7315-0
Image
Gamma
balance
adjustment
7315-1
(PS / Smooth
/ 600dpi)
7315-2
7316-0
Image
Gamma
balance
adjustment
7316-1
(PS / Detail /
600dpi)
7316-2
7317-0
Image
Gamma
balance
adjustment
7317-1
(PCL /
Smooth /
7317-2
600dpi)
7318-0
Image
Gamma
balance
adjustment
7318-1
(PCL / Detail /
600dpi)
7318-2
7319-0
Image
Gamma
balance
adjustment
7319-1
(XPS /
Smooth /
7319-2
600dpi)
7320-0
Image
Gamma
balance
adjustment
7320-1
(XPS / Detail /
600dpi)
7320-2
e-STUDIO2330C/2820C/2830C/3520C/3530C/4520C
ADJUSTMENT MODE (05)
Adjustment mode (05)
Functi
Items
on
Image
PPC
smoothing
(black)
Image
PPC
smoothing
(black)
L
PRT
(black)
M
PRT
(black)
H
PRT
(black)
L
PRT
(black)
M
PRT
(black)
H
PRT
(black)
L
PRT
(black)
M
PRT
(black)
H
PRT
(black)
L
PRT
(black)
M
PRT
(black)
H
PRT
(black)
L
PRT
(black)
M
PRT
(black)
H
PRT
(black)
L
PRT
(black)
M
PRT
(black)
H
PRT
(black)
24 - 38
Default
<Accept
RAM
Contents
able
value>
1
SYS
0: Background peak -
<0-1>
Fixed
1: Background peak -
Varied
0
SYS
0: Background peak -
<0-1>
Fixed
1: Background peak -
Varied
128
SYS
When the value
<0-255>
increases, the density
in the target area
128
SYS
becomes higher.
<0-255>
L: Low density area
128
SYS
M: Medium density
<0-255>
area
H: High density area
128
SYS
When the value
<0-255>
increases, the density
in the target area
128
SYS
becomes higher.
<0-255>
L: Low density area
128
SYS
M: Medium density
<0-255>
area
H: High density area
128
SYS
When the value
<0-255>
increases, the density
in the target area
128
SYS
becomes higher.
<0-255>
L: Low density area
128
SYS
M: Medium density
<0-255>
area
H: High density area
128
SYS
When the value
<0-255>
increases, the density
in the target area
128
SYS
becomes higher.
<0-255>
L: Low density area
128
SYS
M: Medium density
<0-255>
area
H: High density area
128
SYS
When the value
<0-255>
increases, the density
in the target area
128
SYS
becomes higher.
<0-255>
L: Low density area
128
SYS
M: Medium density
<0-255>
area
H: High density area
128
SYS
When the value
<0-255>
increases, the density
in the target area
128
SYS
becomes higher.
<0-255>
L: Low density area
128
SYS
M: Medium density
<0-255>
area
H: High density area
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved
Proce
dure
1
1
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents