Toshiba e-STUDIO2330C Service Manual page 983

Hide thumbs Also See for e-STUDIO2330C:
Table of Contents

Advertisement

Error code
Classification
CE50
Image control related
service call
CE60
CE70
CE71
CE90
CEC0
Copy process related
service call
CF10
Finisher related
service call
CF90
Laser optical unit
related service call
F070
Communication
related service call
F090
Circuit related service
call
F100
Other service call
F101
F102
F103
F104
F105
F106
F107
F108
F110
Communication
related service call
F111
F120
Other service call
F130
F200
F350
Circuit related service
call
F400
Circuit related service
call
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved
Contents
Temperature/humidity sensor abnormality: The
output value of this sensor is out of a specified
range.
Drum thermistor-Y abnormality: The output value of
the drum thermistor-Y is out of a specified range.
Drum drive switching abnormality: The drum
switching detection sensor (S19) is not turned ON
after the drum motor was rotated for a specified
period of time.
Drum phase adjustment abnormality: Drum phase
sensors (Color drum phase sensor (S43) and K
drum phase sensor (S44)) are not turned ON after
the drum motor was rotated for a specified period of
time.
Drum thermistor-K abnormality: The output value of
the drum thermistor-K is out of a specified range.
2nd transfer roller position detection abnormality:
The 2nd transfer roller does not contact/release
normally.
Communication module SRAM reading failure.
[MJ-1101]
Laser optical unit shutter abnormality.
Communication error between System-CPU and
Engine-CPU
SRAM abnormality on the SYS board
HDD format error: HDD cannot be initialized
normally.
HDD unmounted: Connection of HDD cannot be
detected.
HDD start error: HDD cannot become 'Ready' state.
HDD transfer time-out: Reading/writing cannot be
performed in the specified period of time.
HDD data error: Abnormality is detected in the data
of HDD.
HDD other error
Point and Print partition damage
/BOX partition damage
/SHA partition damage
Communication error between System-CPU and
Scanner-CPU
Scanner response abnormality
Database abnormality: Database is not operating
normally.
Invalid MAC address
Data Overwrite option (GP-1070) disabled
SLG board abnormality
SYS board cooling fan abnormality
26 - 13
Troubleshooting
P. 26-97
P. 26-97
P. 26-98
P. 26-99
P. 26-97
P. 26-103
P. 26-86
P. 26-69
P. 26-63
P. 26-65
P. 26-104
P. 26-104
P. 26-104
P. 26-104
P. 26-104
P. 26-104
P. 26-104
P. 26-104
P. 26-104
P. 26-63
P. 26-63
P. 26-104
P. 26-105
P. 26-105
P. 26-66
P. 26-105
e-STUDIO2330C/2820C/2830C/3520C/3530C/4520C
ERROR CODE AND TROUBLESHOOTING
26

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents