7.6.3

Automatic original detection sensor (APS sensor)

[A] A4 series (APS-1, -2, -3, -C, -R)
(1)
Take off the original glass.
 P.7-16 "7.6.1 Original glass"
(2)
Disconnect 1 connector and remove 1 screw
for each APS sensor. Take off 5 APS
sensors.
[B] LT series (APS-1, -3, -C, -R)
(1)
Take off the original glass.
 P.7-16 "7.6.1 Original glass"
(2)
Disconnect 1 connector and remove 1 screw
for each APS sensor. Take off 4 APS
sensors.
7.6.4
Exposure lamp (EXP)
(1)
Take off the original glass and front upper
cover.
 P.7-16 "7.6.1 Original glass"
 P.3-28 "3.5.4 Front upper cover"
(2)
Move the carriage-1 to the center position.
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved