13.6.2

Adjustment of the doctor-to-sleeve gap

For the adjustment of the doctor-to-sleeve gap, perform the same procedure for the Y, M, C and K
developer units.
Adjustment tool to use: Doctor-sleeve gap jig
<Adjustment procedure>
(1)
Take off the process unit from the equipment.
(2)
Take off the developer unit from the process
unit.
 P.12-12 "12.6 Disassembly and
Replacement"
(3)
Take off the developer material cover. Then
discharge the developer material.
Note:
While reattaching the developer material
cover set the latches securely.
(4)
Loosen 2 doctor blade fixing screws. Insert
the gauge "0.65" of the doctor sleeve jig
between the developer sleeve and doctor
blade to adjust the gap, and tighten the
screws.
e-STUDIO2330C/2820C/2830C/3520C/3530C/4520C
DEVELOPER UNIT
Developer material cover
Doctor blade
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved
13 - 38
Developer unit
Fig. 13-77
Fig. 13-78