Toshiba e-STUDIO2330C Service Manual page 526

Hide thumbs Also See for e-STUDIO2330C:
Table of Contents

Advertisement

Notes:
When replacing the system control PC board (SYS board), update with the Download jig.
Written firmware varies depending on the kinds of the boards provided as service parts. For
updating, only the minimum firmware is installed on the system control PC board, logic PC
board, and scanning section control PC board. No firmware is installed on the FAX board. The
latest version of the firmware at the time of delivery is written on the RADF control PC board
and finisher control PC board.
When any of above boards is replaced with a new one in the field, check the other firmware
version used and then update with a corresponding suitable version.
The firmware (master data) is not installed on the hard disk provided as a service part. When
the hard disk is replaced with a new one, check the other firmware version used and then
write a corresponding suitable version.
e-STUDIO2330C/2820C/2830C/3520C/3530C/4520C
FIRMWARE UPDATING
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved
20 - 4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents