13.5.9

Temperature / humidity sensor (S12)

(1)
Take off the waste toner transport auger
drive unit.
 P.13-24 "13.5.8 Waste toner transport
motor (M31)"
(2)
Release the 2 latches. Disconnect the 1
connector and take off the temperature /
humidity sensor.
13.5.10 Waste toner box full detection sensor (S13)
(1)
Take off the waste paddle toner motor drive
unit.
 P.13-27 "13.5.12 Waste toner paddle
motor (M6)"
(2)
Disconnect 1 connector.
(3)
Release 3 latches, and take off the waste
toner box full detection sensor.
13.5.11 Waste toner paddle motor lock detection sensor (S14)
(1)
Take off the waste toner paddle motor drive
unit.
 P.13-27 "13.5.12 Waste toner paddle
motor (M6)"
(2)
Release 2 latches, and take off the gear,
coupling and spring.
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved
Temperature / humidity sensor
Sensor holder
Fig. 13-47
Waste toner box full detection sensor
Fig. 13-48
Coupling
Fig. 13-49
e-STUDIO2330C/2820C/2830C/3520C/3530C/4520C
13 - 25
Spring
Gear