559
Image
Image quality closed-loop
control
control automatic start-up /
At the first power-ON in the
morning
565
Image
Image quality closed-loop
control
control automatic start-up/
Relative humidity variation
566
Image
Image quality closed-loop
control
control automatic start-up/
Period of time unattended
567
Image
Image quality closed-loop
control
control automatic start-up/
Accumulated print volume
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved
Setting mode (08)
Functi
<Accept
Items
on
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
25 - 21
Default
RAM
Contents
able
value>
2
M
Sets whether
<0-2>
performing closed-loop
control automatically at
power-ON when the
fuser roller temperature
becomes below the
specified level.
0: Invalid
1: Valid (mode1: for
Quick Image Quality
Control)
2: Valid (mode2: for
Standard Image
Quality Control)
2
M
Sets whether or not
<0-2>
performing closed-loop
control automatically
when the relative
humidity becomes
below the specified
level from the previous
control.
0: Invalid
1: Valid (mode1: for
Quick Image Quality
Control)
2: Valid (mode2: for
Standard Image
Quality Control)
2
M
Sets whether or not
<0-2>
performing closed-loop
control automatically at
the operation start
when the equipment
has not been used for a
specified period of time
in the energy saving
mode.
0: Invalid
1: Valid (mode1: for
Quick Image Quality
Control)
2: Valid (mode2: for
Standard Image
Quality Control)
2
M
Sets whether or not
<0-2>
performing closed-loop
control automatically
when the specified
number of sheets has
been printed out from
the previous control.
0: Invalid
1: Valid (mode1: for
Quick Image Quality
Control)
2: Valid (mode2: for
Standard Image
Quality Control)
e-STUDIO2330C/2820C/2830C/3520C/3530C/4520C