(8)
Raise the front handle, and then hold it
together with the rear handle (light blue) to
take off the transfer belt unit.
Note:
When taking off the transfer belt unit, be sure
not to contact the bottom of this unit and the
2nd transfer unit to prevent the transfer belt
from being scratched.
Note:
Be careful not to deform the spring when
removing/installing the transfer belt unit.
Notes:
Follow the procedure below for the
installation.
1. Rotate the TBU cleaner pressure hook
lever on the transfer belt unit to lock the
TBU cleaner pressure hook.
2. Check if the TBU release lever is at the
release position (vertical position).
3. Check that the middle guide of the unit is
opened.
4. Insert the transfer belt unit by sliding the
unit along the rail.
5. Store the front handle, and then push the
holder all the way in until it comes to a
stop.
6. When the unit has been securely
inserted, close the middle guide.
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved
Handle
Fig. 14-16
Fig. 14-17
TBU cleanner pressure hook
TBU cleanner
pressure hook lever
Fig. 14-18
e-STUDIO2330C/2820C/2830C/3520C/3530C/4520C
14 - 15
Handle
( light blue )
Transfer belt unit
Spring
TRANSFER UNIT