8.8.2

Density adjustment

Adjusts the center density and the variation of density adjustment buttons.
Original mode
Color
Mode
Text
Photo
Color
8340
8341
8344
8345
8348
8349
Black
Original mode
Text/
Text
Photo
Photo
845
846
847
860
861
862
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Key in a code and press the [START] button.
(3)
Key in an adjustment value (acceptable values: 0 to 255).
(To correct a value once keyed in, press the [CLEAR] button.)
Press the [ENTER] or [INTERRUPT] button to store the value in memory.  The equipment goes
(4)
back to the ready state.
(5)
Let the equipment restart and perform the scanning.
(6)
If the desired image quality has not been attained, repeat step (1) to (5).
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved
Item to be
Printed
User
adjusted
image
custom
8342
8380
Manual density
center value
8346
8381
Manual density
light step value
8350
8382
Manual density
dark step value
Gray
Item to be
Scale
adjusted
User
custom
7475
848
Manual density
center value
7478
863
Automatic density
8 - 63
<Adjustment Mode (05)>
Remarks
The larger the value is, the darker the image
becomes.
Acceptable values: 0 to 255 (Default: 128)
Sets the changing amount by 1 step at the
density adjustment on the control panel.
The larger the value is, the lighter the light
side becomes.
Acceptable values: 0 to 255 (Default: 20)
Sets the changing amount by 1 step at the
density adjustment on the control panel.
The larger the value is, the darker the dark
side becomes.
Acceptable values: 0 to 255 (Default: 20)
<Adjustment Mode (05)>
Remarks
The larger the value is, the darker the image
becomes.
Acceptable values: 0 to 255
(Default: 128)