3.9
Adjustment of the doctor-to-sleeve gap
For the adjustment of the doctor-to-sleeve gap, perform the same procedure for the Y, M, C and K
developer units.
Adjustment tool to use: Doctor-sleeve gap jig
<Adjustment procedure>
(1)
Take off the process unit from the equipment.
(2)
Take off the developer unit from the process
unit.
SERVICE MANUAL "12.6 Disassembly
and Replacement"
(3)
Take off the developer material cover. Then
discharge the developer material.
Note:
While reattaching the developer material
cover set the latches securely.
(4)
Loosen 2 doctor blade fixing screws. Insert
the gauge "0.65" of the doctor sleeve jig
between the developer sleeve and doctor
blade to adjust the gap, and tighten the
screws.
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved
Developer material cover
Fig. 3-32
Doctor blade
Fig. 3-33
e-STUDIO2330C/2820C/2830C/3520C/3530C/4520C
3 - 69
Developer unit
ADJUSTMENT
3