Utility mode
"ON (Without Login)" allows the machine to be used without au-
thentication when logging on as a public user. When logging on as
an authorized user, the [Access] key must be pressed first to dis-
play the authentication screen.
6
Specify a setting for "Account Track".
To cancel account tracking, touch [OFF].
To use the account track function, touch [ON].
7
Specify a setting for "Account Track Input Method".
To allow this machine to be used after the account name and
password are entered in the account track screen, touch [Account
Name & Password].
To allow this machine to be used after the password is entered in
the account track screen, touch [Password Only].
8
Specify a setting for "Synchronize User Authentication & Account
Track".
Synchronize
"ON (MFP)" is set and "Account Track" is set to "ON", this setting
allows this machine to be used simply by entering user
authentication information the first time that the machine is used if
the corresponding account was specified during user registration.
If "External Server Authentication" is set and "Account Track" is set
to "ON", this setting allows the machine to be used simply by
entering user authentication information after the machine has been
used once with the appropriate user authentication and account
track information entered.
Do Not Synchronize
This setting requires that all information be entered for user
authentication and account track each time that the machine is
used.
9
Touch [↓].
The second screen is displayed.
10
Specify a setting for "When # of Jobs Reach Maximum".
To skip the job when the limit specified with account track is
reached, touch [Skip Job].
cm4521
11
11-101