IBM Flex System p270 Compute Node Installation And Service Manual page 47

Table of Contents

Advertisement

Figure 7. Installing the cover for an IBM Flex System p270 Compute Node
Statement 21
CAUTION:
Hazardous energy is present when the compute node is connected to the power source. Always replace
the compute node cover before you install the compute node.
To replace and close the compute node cover, complete the following steps:
Procedure
1. Read the Safety topic and the "Installation guidelines" on page 29.
2. Lower the cover so that the pins on the sides of the cover slide down into the slots (as shown in the
preceding figure) at the front and rear of the compute node. Before you close the cover, verify that all
components are installed and seated correctly and that you have not left loose tools or parts inside the
compute node.
3. Slide the cover forward to the closed position until the releases click into place in the cover.
Chapter 6. Installing and removing components
35

Advertisement

Table of Contents
loading

Table of Contents