IBM Flex System p270 Compute Node Installation And Service Manual page 182

Table of Contents

Advertisement

B7005603 • B7006909
B7005603
Explanation: Enclosure feature code and/or serial number not valid.
Response: Verify that the machine type, model, and serial number are correct for this server.
B7006900
Explanation: PCI host bridge failure
Response:
1. Replace the system-board, as described in Replacing the system-board and chassis assembly.
2.
If the problem persists, use the PCI expansion card (PIOCARD) problem isolation procedure to determine the
failing component.
B7006906
Explanation: System bus error
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B7006907
Explanation: System bus error
Response:
1. Replace the system-board, as described in Replacing the system-board and chassis assembly.
2. Go to Isolating firmware problems.
B7006908
Explanation: System bus error
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B7006909
Explanation: System bus error
Response:
1. Replace the system-board, as described in Replacing the system-board and chassis assembly.
2. Go to Isolating firmware problems.
170
Power Systems: IBM Flex System p270 Compute Node Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents