IBM Flex System p270 Compute Node Installation And Service Manual page 468

Table of Contents

Advertisement

Table 16. Hypervisor isolation procedures and symbolic failing items (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 7, "Parts listing for IBM Flex System p270 Compute Node," on page 95 to determine which
components are CRUs and which components are FRUs.
v If an action step is preceded by Trained service technician only, that step must be performed only by a trained
service technician.
Isolation
procedure or
Symptom
symbolic failing
item
The path to the
PSI_LNK
service processor
might be the failing
item.
SICNTRL
This item does not apply to compute nodes. Continue with the next item in the failing item list.
SIIOADP
The I/O hub or I/O
bridge might be
failing.
SLOTUSE
The card in the given
slot is not available
for use.
SVCDOCS
Read the description of the system reference code (SRC) and perform any actions indicated
there. If you have already read and performed the actions in the description, go to the next
failing item in the failing item list.
SVCPROC
The service processor
is failing.
456
Power Systems: IBM Flex System p270 Compute Node Installation and Service Guide
Action
Replace the system-board and chassis assembly, as described in
"Replacing the system-board and chassis assembly" on page 83.
Replace the system-board and chassis assembly, as described in
"Replacing the system-board and chassis assembly" on page 83.
1. Is the SRC B2002250 or B2002300?
No:
Continue with step 3.
Yes:
The first two characters in word 4 of the reference code will
identify the platform Licensed Internal Code component that
has control of the slot. Continue with the next step.
2. What is the value of the first two characters of word 4 of the
reference code?
v 02 or 03: The management console has control of the slot. Make
sure that management console is not using the slot. This ends the
procedure.
v Other: Contact your next level of support. This ends the
procedure.
3. Is the SRC B2002475?
No:
Contact your next level of support. This ends the
procedure.
Yes:
Continue with the next step.
4. Look in the event log for part numbers and location codes associated
with the card slot.
Note: There will not be a part number if the card slot is empty.
Check the server to see if a card is physically present in the card slot.
Is a card physically present?
No:
Use symbolic FRU LPARCFG to reconfigure the card slot so
that it is not a required resource to perform a partition IPL.
This ends the procedure.
Yes:
Replace the failing card. This ends the procedure.
Replace the system-board and chassis assembly, as described in
"Replacing the system-board and chassis assembly" on page 83.

Advertisement

Table of Contents
loading

Table of Contents