IBM Flex System p270 Compute Node Installation And Service Manual page 444

Table of Contents

Advertisement

SSSS-116 • SSSS-120
SSSS-116
Explanation: A protocol error.
1. Make sure that the device, adapter and diagnostic firmware, and the application software levels are compatible.
2. If you do not find a problem, call your operating-system support person.
Response:
Failing Item:
v FFC_SSSS
SSSS-117
Explanation: A write-protect error occurred.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in Replacing the system-board and chassis assembly.
Response:
Failing Item:
v FFC_SSSS
SSSS-118
Explanation: A SCSD command time-out occurred.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in Replacing the system-board and chassis assembly.
Response:
Failing Item:
v FFC_SSSS
v FFC_252B
SSSS-120
Explanation: A SCSD busy or command error.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in Replacing the system-board and chassis assembly.
Response:
Failing Item:
v FFC_SSSS
432