BA030011 • BA040030
BA030011
Explanation: RTAS attempt to allocate memory failed
Response:
1. Reboot the server.
2. If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA04000F
Explanation: Self test failed on device; no error or location code information is available
Response:
1. Reboot the server.
2. If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA040010
Explanation: Self test failed on device; can't locate package.
Response:
1. If a location code is listed with the error, replace the device specified by the location code.
2. If a location code was not listed with the error: Search RETAIN tips and the firmware change history for the
reference code to determine the recommended actions. If a firmware update is needed, see Updating the firmware
BA040020
Explanation: The machine type and model are not recognized by the server firmware.
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA040030
Explanation: The firmware was not able to build the UID properly for this system. As a result, problems may occur
with the licensing of the AIX operating system.
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware