IBM Flex System p270 Compute Node Installation And Service Manual page 341

Table of Contents

Advertisement

2604-704 • 2607-102
2604-704
Explanation: Error Log Analysis indicates that an adapter error has occurred for the Fibre Channel adapter card. Go
to Performing the checkout procedure.
Response:
Failing Item:
v FFC_2604
2604-705
Explanation: Error Log Analysis indicates that a parity error has been detected for the Fibre Channel adapter card.
The adapter must be replaced immediately. Failure to do so could result in data being read or written incorrectly.
Response:
Failing Item:
v FFC_2604
2604-706
Explanation: Error Log Analysis indicates that a fatal hardware error has occurred for the Fibre Channel adapter
card.
This adapter was successfully taken off-line. It will remain off-line until reconfigured or the system is rebooted. This
adapter must be replaced and not brought back on-line. Failure to adhere to this action could result in data being
read or written incorrectly or in the loss of data.
Response:
Failing Item:
v FFC_2604
2604-XXX
Explanation: Generic reference for 4Gb Fibre Channel Adapter card. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_2604
2607-102
Explanation: Reset Test failure for the Fibre Channel adapter card. Replace the 8Gb PCIe Fibre Channel Expansion
Card.
Response:
Failing Item:
v FFC_2607
329
Chapter 8. Troubleshooting