IBM Flex System p270 Compute Node Installation And Service Manual page 162

Table of Contents

Advertisement

B2006025 • B2008081
B2006025
Explanation: A problem occurred during the startup of a partition. This is a problem with the load source media
being corrupt or not valid.
Response: Replace the load source media.
B2006027
Explanation: During the startup of a partition, a failure occurred when allocating memory for an internal object
used for firmware module load operations.
Response:
1. Make sure that enough main storage was allocated to the partition.
2. Retry the operation.
B2006110
Explanation: A problem occurred during the startup of a partition. There was an error on the load source device.
The startup will attempt to continue.
Response: Look for other errors and resolve them.
B200690A
Explanation: During the startup of a partition, an error occurred while copying open firmware into the partition
load area.
Response: Go to Isolating firmware problems.
B2007200
Explanation: Informational system log entry only.
Response: No corrective action is required.
B2008080
Explanation: Informational system log entry only.
Response: No corrective action is required.
B2008081
Explanation: During the startup of a partition, an internal firmware time-out occurred; the partition might continue
to start up but it can experience problems while running.
Response: Check for server firmware updates; then, install the updates if available.
150
Power Systems: IBM Flex System p270 Compute Node Installation and Service Guide