652-613 • 652-632
652-613
Explanation: A non-critical error has been detected: external cache ECC single-bit error. Schedule deferred
maintenance. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_D01
652-623
Explanation: A non-critical error has been detected: correctable error threshold exceeded. Schedule deferred
maintenance. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_2C6
652-630
Explanation: A non-critical error has been detected: I/O expansion bus parity error. Schedule deferred maintenance.
Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_307
652-631
Explanation: A non-critical error has been detected: I/O expansion bus time-out error. Schedule deferred
maintenance. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_307
652-632
Explanation: A non-critical error has been detected: I/O expansion bus connection failure. Schedule deferred
maintenance. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_307