CA00E179 • CA00E19A
CA00E179
Explanation: Closing BOOTP
Response:
1. Verify that:
v The bootp server is correctly configured; then, retry the operation.
v The network connections are correct; then, retry the operation.
2. If the problem persists:
a. Go to Checkout procedure.
b. Replace the system-board, as described in Replacing the system-board and chassis assembly.
CA00E17B
Explanation: Microprocessor clock speed measurement
Response:
1. Go to Checkout procedure.
2. Replace the system-board, as described in Replacing the system-board and chassis assembly.
CA00E198
Explanation: The system is rebooting to enact changes that were specified in ibm,client-architecture-support
Response: Go to Boot problem resolution.
CA00E199
Explanation: The system is rebooting to enact changes that were specified in the boot image ELF header
Response:
1. Verify that:
v The bootp server is correctly configured; then, retry the operation.
v The network connections are correct; then, retry the operation.
2. If the problem persists:
a. Go to Checkout procedure.
b. Replace the system-board, as described in Replacing the system-board and chassis assembly.
CA00E19A
Explanation: NVRAM auto-boot? variable not found - assume FALSE
Response:
1. Go to Checkout procedure.
2. Replace the system-board, as described in Replacing the system-board and chassis assembly.
266
Power Systems: IBM Flex System p270 Compute Node Installation and Service Guide