IBM Flex System p270 Compute Node Installation And Service Manual page 408

Table of Contents

Advertisement

2E37-154 • 2E37-702
2E37-154
Explanation: Internal loopback UDP checksum offload test failed. Replace the IBM Flex System EN4054 4-port 10Gb
Ethernet Adapter.
Response:
Failing Item:
v FFC_2E37
2E37-155
Explanation: Internal loopback LSO test failed. Replace the IBM Flex System EN4054 4-port 10Gb Ethernet Adapter.
Response:
Failing Item:
v FFC_2E37
2E37-201
Explanation: Registers test failed. Replace the IBM Flex System EN4054 4-port 10Gb Ethernet Adapter. If the
problem persists, replace the system board.
Response:
Failing Item:
v FFC_2E37
v FFC_221
2E37-701
Explanation: Adapter hardware error. Replace the IBM Flex System EN4054 4-port 10Gb Ethernet Adapter.
Response:
Failing Item:
v FFC_2E37
2E37-702
Explanation: EEH service error. Replace the IBM Flex System EN4054 4-port 10Gb Ethernet Adapter. If the problem
persists, replace the system board.
Response:
Failing Item:
v FFC_2E37
v FFC_221