IBM Flex System p270 Compute Node Installation And Service Manual page 197

Table of Contents

Advertisement

BA00E850
Explanation: Failure when initializing dynamic reconfiguration
Response:
1. Reboot the server.
2. If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA00E860
Explanation: Failure when initializing sensors
Response:
1. Reboot the server.
2. If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA010000
Explanation: There is insufficient information to boot the server
Response:
1. Reboot the server.
2. If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA010001
Explanation: The client IP address is already in use by another network device
Response: Verify that all of the IP addresses on the network are unique; then, retry the operation.
BA010002
Explanation: Cannot get gateway IP address
Response: Perform the following actions that checkpoint CA00E174 describes:
1. Verify that:
v The bootp server is correctly configured; then, retry the operation.
v The network connections are correct; then, retry the operation.
2. If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA00E850 • BA010002