IBM Flex System p270 Compute Node Installation And Service Manual page 328

Table of Contents

Advertisement

887-402 • 101-XXXX
887-402
Explanation: Ethernet 10 Base-2 transceiver test failed. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_887
887-403
Explanation: Ethernet 10 Base-T transceiver test failed. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_887
887-405
Explanation: Ethernet- network Rerun diagnostics in advanced mode for accurate problem determination. Go to
Performing the checkout procedure.
Response:
Failing Item:
v FFC_887
101-2020
Explanation: The system hung while trying to configure the InfiniBand Communication Manager. This problem may
be attributed to software. Report this problem to the AIX Support Center.
Response:
101-2021
Explanation: The system hung while trying to configure the InfiniBand TCP/IP Interface. This problem may be
attributed to software. Report this problem to the AIX Support Center.
Response:
101-XXXX
Explanation: The system hung while configuring a resource. The last three or four digits after the dash (-) identify
the failing function code for the resource being configured. Go to undetermined problem procedure.
Response:
Failing Item:
v FFC_XXXX
316
Power Systems: IBM Flex System p270 Compute Node Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents