B2001260
Explanation: A problem occurred during the startup of a partition.
The partition could not start at the Timed Power On setting because the partition was not set to Normal.
Response: Set the partition to Normal.
B2001265
Explanation: The partition could not start up. An operating system Main Storage Dump startup was attempted with
the startup side on D-mode, which is not a valid operating system startup scenario. The startup will be halted. This
SRC can occur when a D-mode SLIC installation fails and attempts a Main Storage Dump.
Response: Correct the startup settings.
B2001266
Explanation: The partition could not start up. You are attempting to start up an operating system that is not
supported.
Response: Install a supported operating system and restart the partition.
B2001280
Explanation: A problem occurred during a partition Main Storage Dump. A mainstore dump startup did not
complete due to a configuration mismatch.
Response: Go to Isolating firmware problems.
B2001281
Explanation: A partition memory error occurred. The failed memory will no longer be used.
Response: Restart the partition.
B2001282
Explanation: A problem occurred during the startup of a partition.
Response: Go to Isolating firmware problems.
B2001320
Explanation: A problem occurred during the startup of a partition.
No default load source was selected. The startup will attempt to continue, but there may not be enough information
to find the correct load source.
Response: Configure a load source for the partition. Then restart the partition.
140
Power Systems: IBM Flex System p270 Compute Node Installation and Service Guide