B2008105 • B2008114
B2008105
Explanation: During the startup of a partition, there was a failure loading the VPD areas of the partition; the load
source media has been corrupted or is unsupported on this server.
Response: Check for server firmware updates; then, install the updates if available.
B2008106
Explanation: A problem occurred during the startup of a partition. The startup will not continue.
Response: Replace the load source media.
B2008107
Explanation: During the startup of a partition, there was a problem getting a segment of main storage in the server
main storage.
Response: Check for server firmware updates; then, install the updates if available.
B2008109
Explanation: During the startup of a partition, a failure occurred. The startup will not continue.
Response:
1. Make sure that there is enough memory to start up the partition.
2. Check for server firmware updates; then, install the updates if available.
B2008111
Explanation: A problem occurred during the startup of a partition.
Response: Check for server firmware updates; then, install the updates if available.
B2008112
Explanation: During the startup of a partition, a failure occurred; the startup will not continue.
Response: Check for server firmware updates; then, install the updates if available.
B2008113
Explanation: During the startup of a partition, an error occurred while mapping memory for the partition startup.
Response: Check for server firmware updates; then, install the updates if available.
B2008114
Explanation: During the startup of a partition, there was a failure verifying the VPD for the partition resources
during startup.
Response: Check for server firmware updates; then, install the updates if available.
151