IBM Flex System p270 Compute Node Installation And Service Manual page 333

Table of Contents

Advertisement

252B-723 • 254E-603
252B-723
Explanation: Device bus interface problem.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_252B
254E-201
Explanation: Adapter configuration error. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_254E
v FFC_221
254E-601
Explanation: Error log analysis indicates adapter failure. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_254
254E-602
Explanation: Error log analysis indicates an error attention condition. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_254
254E-603
Explanation: Error log analysis indicates that the microcode could not be loaded on the adapter. Go to Performing
the checkout procedure.
Response:
Failing Item:
v FFC_254
321
Chapter 8. Troubleshooting

Advertisement

Table of Contents
loading

Table of Contents