268B-120 • 268B-128
268B-120
Explanation: A SCSI busy or command error. Replace the 300 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_268B
268B-122
Explanation: A SCSI reservation conflict error. Replace the 300 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_268B
268B-124
Explanation: A SCSI check condition error occurred. Replace the 300 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_268B
268B-126
Explanation: A software error was caused by a hardware failure. Replace the 300 GB SFF SAS Hard Disk Drive. Run
diagnostics again on the drive. If the error repeats, replace the 2nd FRU identified by diagnostics.
Response:
Failing Item:
v FFC_268B
v FFC_B88
268B-128
Explanation: The error log analysis indicates a hardware failure. Replace each part reported by the diagnostic
program one at a time. Run the diagnostic program in problem determination mode on each part reported in the
original SRN. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_B88
v FFC_268B