B2008152
Explanation: No active system processors.
Response: Verify that processor resources are assigned to the partition.
B2008160
Explanation: A problem occurred during the migration of a partition.
Response: Contact IBM support.
B2008161
Explanation: A problem occurred during the migration of a partition.
Response: Contact IBM support.
B200A100
Explanation: A partition ended abnormally; the partition could not stay running and shut itself down.
Response:
1. Check the error logs and take the actions for the error codes that are found.
2. Go to Isolating firmware problems.
B200A101
Explanation: A partition ended abnormally; the partition could not stay running and shut itself down.
Response:
1. Check the error logs and take the actions for the error codes that are found.
2. Go to Isolating firmware problems.
B200A140
Explanation: A lower priority partition lost a usable processor to supply it to a higher priority partition with a bad
processor.
Response: Evaluate the entire LPAR configuration. Adjust partition profiles with the new number of processors
available in the system.
B200B07B
Explanation: Informational system log entry only.
Response: No corrective action is required.