IBM Flex System p270 Compute Node Installation And Service Manual page 218

Table of Contents

Advertisement

BA140003 • BA151002
BA140003
Explanation: The SCSD read/write optical send diagnostic failed; sense data available.
Response:
1. Troubleshoot the SCSD devices.
2. Verify that the SCSD cables and devices are properly plugged. Correct any problems that are found.
3. Replace the SCSD cables and devices.
4. If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA140004
Explanation: The SCSD read/write optical send diagnostic failed; devofl command.
Response:
1. Troubleshoot the SCSD devices.
2. Verify that the SCSD cables and devices are properly plugged. Correct any problems that are found.
3. Replace the SCSD cables and devices.
4. If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA150001
Explanation: PCI Ethernet BNC/RJ-45 or PCI Ethernet AUI/RJ-45 adapter: internal wrap test failure
Response: Replace the adapter specified by the location code.
BA151001
Explanation: 10/100 Mbps Ethernet PCI adapter: internal wrap test failure
Response: Replace the adapter specified by the location code.
BA151002
Explanation: 10/100 Mbps Ethernet card failure
Response:
1. Reboot the server.
2. Check for server firmware updates; install the updates if available.
3. Replace the adapter specified by the location code.
4. If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
206
Power Systems: IBM Flex System p270 Compute Node Installation and Service Guide