AA060011 • AA190001
AA060011
Explanation: The firmware did not find an operating system image and at least one hard disk in the boot list was
not detected by the firmware. The firmware is retrying the entries in the boot list.
Response: This might occur if a disk enclosure that contains the boot disk is not fully initialized or if the boot disk
belongs to another partition. Verify that:
v The boot disk belongs to the partition from which you are trying to boot.
v The boot list in the SMS menus is correct.
AA130013
Explanation: Bootable media is missing from a USB CD-ROM
Response: Verify that a bootable CD is properly inserted in the CD or DVD drive and retry the boot operation.
AA130014
Explanation: The media in a USB CD-ROM has changed.
Response:
1. Retry the operation.
2. Check for server firmware updates; then, install the updates if available and retry the operation.
AA170210
Explanation: Setenv/$setenv parameter error - the name contains a null character.
Response:
1. Go to Checkout procedure.
2. Replace the system-board, as described in Replacing the system-board and chassis assembly.
AA170211
Explanation: Setenv/$setenv parameter error - the value contains a null character.
Response:
1. Go to Checkout procedure.
2. Replace the system-board, as described in Replacing the system-board and chassis assembly.
AA190001
Explanation: The hypervisor function to get or set the time-of-day clock reported an error.
Response:
1. Use the operating system to set the system clock.
2. If the problem persists, check for server firmware updates.
3. Install any available updates and retry the operation.