BA210011
Explanation: The transfer of control to the IO reporter failed
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA210012
Explanation: There was an NVRAMRC forced-boot problem; unable to load the previous boot's operating system
image
Response:
1. Use the SMS menus to verify that the partition firmware can still detect the operating system image.
2. Reboot the server.
3. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA210013
Explanation: There was a partition firmware error when in the SMS menus.
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA210020
Explanation: I/O configuration exceeded the maximum size allowed by partition firmware.
Response:
1. Increase the logical memory block size to 256 MB and restart the server.
2. Reboot the server.
3. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA210100
Explanation: An error may not have been sent to the management module event log.
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA210011 • BA210100